3930

Service Delivery Switch

Ciena’s 3930 Service Delivery Switch is an advanced packet networking system focused on the transition to high-bandwidth applications requiring sophisticated Quality of Service (QoS) capabilities, including mobile backhaul and Ethernet business services.

Features

Provides advanced Carrier Ethernet and low TCO, powered by Ciena’s Service-Aware Operating System (SAOS)

Supports 2 1GbE/10GbE NNI ports to deliver exceptional capacity for bandwidth-hungry applications

Supports 8 GbE UNI ports including 4 100/1000Base-X Small Form-factor Pluggable (SFP) ports and 4 dual-mode ports: RJ-45 10/100/1000 Base-TX and 100/1000Base-X SFPs

Incorporates on-board Y.1564 and RFC 2544 Performance Benchmark testing capabilities, enabling end-to-end SLA verification without a truck roll

Includes environmentally hardened electronics (-40°C to +65°C) and external alarm inputs, providing flexible deployment options

Provides advanced synchronications support

Specs

  • + Interfaces
    • 2 x 1/10G SFP+ NNI ports
    • 4 x 100/1000M SFP UNI ports
    • 4 x 10/100/1000M RJ-45; 100/1000M SFP UNI combo ports
    • 1 x Console Port (RJ-45, EIA-561)
    • 16 x External Alarm Inputs
    • 1 x RJ45 sync input/output port
    • 2 x mini-SMB sync input/output ports
  • + Ethernet
    • IEEE 802.3 Ethernet
    • IEEE 802.3u Fast Ethernet
    • IEEE 802.3z Gigabit Ethernet
    • IEEE 802.1D MAC Bridges
    • IEEE 802.1Q VLANs - Including .1p Priority
    • IEEE 802.1ad Provider Bridging (Q-in-Q) VLAN full S-VLAN range
    • VLAN tunneling (Q-in-Q) for Transparent LAN Services (TLS)
    • Per-VLAN MAC Learning Control
    • Per-Port MAC Learning Control
    • IEEE 802.3ad Link Aggregation Control Protocol (LACP)
    • ITU-T G.8032 Ethernet Ring Protection Switching
    • Jumbo Frames to 9216 bytes
    • Layer 2 Control Frame Tunneling
    • MEF CE 2.0 Certified:
      • E-LINE: EPL, EVPL
      • E-LAN: EP-LAN, EVP-LAN
      • E-Access: Access EPL, Access EVPL
      • E-Tree: EP-Tree, EVP-Tree
  • + Multicast Management
    • RFC 2236 IGMPv2 Snooping
    • IGMP Domains
    • IGMP Message Filtering
    • IGMP Inquisitive Leave
    • Broadcast/Multicast Storm Control
    • Unknown Multicast Filtering
    • Well-known Protocol Forwarding
  • + Quality of Service
    • 8 Hardware Queues per-Port
    • Committed and Excess Information Rate (CIR and EIR)
    • Classification based on IEEE 802.1D priority VLAN, source port, destination port, TCP/UDP port IIP Precedence and IPDSCP
    • Layer 2, 3, 4 Quality of Service
    • Ingress metering per-port
    • Ingress metering per-port per-CoS
    • Ingress metering per-port per-VLAN
    • Up to ~2000 Ingress Meters per-port
    • Up to 2048 Ingress Meters per-system
    • C-VLAN Priority to S-VLAN Priority Mapping
    • S-VLAN Priority based on C-VLAN ID
    • Per-VLAN Classification, Metering, and Statistics
    • Per-port, per-VLAN QoS with CIR and EIR traffic on Egress Queues
  • + Synchronization
    • ITU-T G.8262/G.8264 SyncE
    • IEEE 1588v2 (OC, TC & BC)*
    • ITU-T G.8261*
    • ITU-T G.8265/G8265.1*
    • ITU-T G.8271*
    • ITU-T G.8275/G.8275.1/G.8275.2*
    • Stratum3E oscillator
    • External Timing Interfaces
    • BITS in or out (1.544MHz, 2.048MHz, 2Mb/s, 64kcc/6312kcc)
    • 10MHz, 1.544MHz, 2.048MHz in or out*
    • 1pps in or out*
    • ToD in or out*
  • + Carrier Ethernet OAM
    • IEEE 802.1ag Connectivity Fault Management (CFM)
    • IEEE 802.3ah Ethernet in the First Mile (EFM)
    • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
    • ITU-T Y.1564 Ethernet Service Activation Test Methodology
    • RFC 2544 Performance Benchmarking Test Generation and Reflection
    • ITU-T Y.1564-compliant architecture
    • RFC 5618 TWAMP Responder and Receiver
    • TWAMP Sender
    • TWAMP +/- 1ms timestamp accuracy
    • Dying Gasp with Syslog and SNMP Traps
  • + MPLS/VPLS
    • RFC 2205, 3031, 3036, 3985 MPLS Pseudowire Emulation Edge-to-Edge (PWE3)
    • RFC 3916, 3985, 4446, 4447, 4448 Pseudowires
    • RFC 5654 MPLS-Transport Profile (TP)
      • LSP Static provisioning
      • 1:1 Tunnel protection
      • LSP BFD via Gal/Gach
    • MPLS Virtual Private Wire Service (VPWS)
    • RFC 4664, 4665 L2VPNs
    • RFC 4762 VPLS (Virtual Private LAN Service) and Hierarchical VPLS (H-VPLS)
    • Provider Edge (PE-rs) Functionality for VPLS and H-VPLS
    • PE-rs Functionality with Spoke and Mesh Virtual Circuits
    • MTU-s Functionality for H-VPLS deployment
    • MTU-s Multihoming (redundant VCs to different PE-s switches)
    • MPLS Virtual Circuit as H-VPLS spoke Virtual Circuit
    • PBB-TE Service Instance as H-VPLS spoke Virtual Circuit
    • Q-in-Q Ethernet Virtual Circuit as H-VPLS spoke Virtual Circuit
    • MPLS Label Switch Path (LSP) Tunnel Redundancy
    • Layer 2 Control Frame Tunneling over MPLS Virtual Circuits
    • RFC 3209 RSVP-TE (for MPLS Tunnel Signaling)
    • RFC 3630 OSPF-TE (for MPLS Tunnel Routes)
    • RFC 3784 IS-IS-TE (for MPLS Tunnel Routes)
    • RFC 3036 Targeted LDP (for VPLS VC signaling)
    • RFC 4090 MPLS Fast ReRoute (via RSVP-TE)
    • MPLS Performance Monitoring
    • RFC 4379 LSP Ping
    • RFC 4379 LSP Traceroute
    • RFC 5085 LSP Ping and Traceroute extensions to work over Pseudowires (PW VCCV)
  • + PBB-TE (Provider Backbone Bridging - Traffic Engineering)
    • IEEE 802.1Qay PBB-TE
    • IEEE 802.1ah PBB frame format
    • PBB-TE Multi-homed Protection Failover
    • IEEE 802.1ag CFM for PBB-TE Tunnels
    • IEEE 802.1ag CFM for PBB-TE Service Interfaces
    • PBB-TE Full B-VID & I-SID address ranges
    • PBB-TE Tunnel & Service metering
  • + Service Security
    • Egress Port Restriction
    • IEEE 802.1X Port-Based Network Access Control (RADIUS/MD5)
    • Layer 2, 3, 4 Protocol Filtering
    • Broadcast Containment
    • User Access Rights
    • Per-port or per-VLAN Service Access Control
    • Hardware-based DOS Attack Prevention
    • Hardware-based Access Control Lists (ACLs)
  • + Network Management
    • Enhanced CLI
    • CLI-based configuration files
    • SNMP v1/v2c/v3
    • SNMPv3 Authentication and Message Encryption
    • RFC 1213 SNMP MIB II
    • RFC 1493 Bridge MIB
    • RFC 1643 Ethernet-like Interface MIB
    • RFC 1573 MIB II interfaces
    • RFC 1757 RMON MIB - including persistent configuration
    • RFC 2021 RMON II and RMON Statistics
    • Per-VLAN Statistics
    • RADIUS Client and RADIUS Authentication
    • TACACS + AAA
    • RFC 2131 DHCP Client
    • RFC 1305 NTP Client
    • RFC 1035 DNS Client
    • Telnet Server
    • RFC 1350 Trivial File Transfer Protocol (TFTP)
    • RFC 959 File Transfer Protocol (FTP)
    • Secure File Transfer Protocol (SFTP)
    • Secure Shell (SSHv2)
    • Syslog with Syslog Accounting
    • Port State Mirroring
    • Local Console Port
    • Comprehensive Management via Ethernet Services Manager
    • Remote Autoconfiguration via TFTP, SFTP
    • Software download/upgrade via TFTP, SFTP
  • + MAC Address Table Capacity
    • 32,000 MAC addresses
  • + Power Requirements
    • DC Input: -48, -36, +36, -24, +24 VDC (nominal)
    • AC Input: 100V, 240V AC (nominal)
    • AC Frequency: 50/60 Hz
    • Maximum Power Input: 75 to 95W, depends on variant
  • + Agency Approvals
    • Safety: UL/CSA 60950-1-07; IEC 60950-1:2005 (2nd edition); EN 60950-1:2006
    • Emissions: FCC Part 15 (2009); EN55022 (2006 +A1 2006); AS/NZS CISPR 22 (2006); CISPR 22 (2005 + A1 2005); ICES-003 Issue 4 (2004); EN
    • 61000-3-2 (2006); EN 300 386 (v1.4.1, 2008); EN 300 132-2 (2007-10); EN 300 132-3 (2003-08)
    • Environmental: WEEE 2002/96/EC RoHS 2002/95/EC
    • Immunity: CISPR 24 (1997, +A1 2001 + A2 2002); EN 55024 (1998 + A1 2001 + A2 2003); EN 300 386 (v1.4.1, 2008); EN 61000- 4-11 (2005); EN
    • 61000-3-3 (2008); EN 300 132-2 (2007-10) ; EN 300 132-3 (2003-08)
    • Laser Safety: CDRH Letter of Approval (US FDA Approval); FCC 21 CFR subpart (J) (Safety of Laser Products); IEC 60825-1:2007
  • + Environmental Characteristics
    • GR-63-CORE, Issue 3 – NEBS Level 3
    • GR-1089 Issue 5 – NEBS Level 3
    • GR-950 Issue 2 Optical Network Unit
    • GR-3108 Issue 2 Network Equipment in the Outside Plant (OSP) Class 2
    • ETSI 300 019 Class 1.1, 2.2, 3.1
    • Operating Temperature:
      • -40°F to +149°F (-40°C to +65°C)
    • Storage Temperature:
      • -40°F to +158°F (-40°C to +70°C)
    • Relative Humidity: 5% to 100% (condensing)
  • + Physical Characteristics
    • Dimensions: 17.5" (W) x 9.9" (D) x 1.75 " (H); 444mm (W) x 252mm (D) x 44mm (H)
    • Weight: 11.0 lbs; 5.0 kg

* Denotes features available in a future release


Ciena may from time to time make changes to the products or
specifications contained herein without notice. Copyright © 2013 Ciena® Corporation. All rights reserved. DS210 4.2013

 

3D Product View

Questions? Ask the community

Ask us

Want to know more about the 3930? Let's talk.

Contact us