+ See all specs
  • +Physical Dimensions
    • 6500-2:
      • 2U 89 mm (H) x 443.2 mm (W) x 281 mm (D)
      • 2U 3.5 in. (H) x 17.5 in. (W) x 11.1 in. (D)
    • 6500-7:
      • 6U 267 mm (H) x 440.5 mm (W) x 281 mm (D)
      • 6U 10.5 in. (H) x 17.3 in. (W) x 11.1 in. (D)
    • 6500-14:
      • 13U 577.1 mm (H) x 440.5 mm (W) x 277.5 mm (D)
      • 13U 22.7 in. (H) x 17.3 in. (W) x 10.9 in. (D)
    • 6500-32:
      • 22U 977 mm (H) x 498.0 mm (W) x 277.5 mm (D)
      • 22U 38.5 in. (H) x 19.6 in. (W) x 277.5 mm (D)
  • +Capacity
    • SONET/SDH: 640 Gb/s
    • Packet/OTN: 3.2 Tb/s
    • System: 96 Tb/s
    • WDM: 2.5G/10G/40G/100G DWDM, 2.5G CWDM
    • Wavelength support: 96 wavelengths in C-band, full band tunable optics
    • SONET/SDH XC: 20G to 80G low order, 80G to 640G high order
    • Packet/OTN XC: 600G to 3.2T
  • +Photonics
    • Full suite of passive filters, 50GHz, 100GHz, flexible grid ROADMs, EDFAs, smart Raman, and Channel Mux/Demux options
  • +Services
    • Ethernet: 10M, 100M, GbE, 40GbE, 100GbE
    • OTN: OTU0 to OTU4
    • FC100 to FC1200
    • SONET/SDH: OC-3/STM-1 through OC-768/STM-256
    • Electrical: DS1, E1, DS3, E3, STM-1e
    • ESCON
    • DVB-ASI
  • +Transponders/Muxponders
    • Coherent 100G line cards: metro, regional, long haul, ultra long haul, enhanced PMD, submarine, colorless
    • Coherent 100G client cards: 10x10GE, 10x10G multi-rate, 100GbE/OTU4 client
    • Coherent 40G line cards: metro, regional, long haul, ultra long haul, enhanced PMD, submarine, colorless
    • Coherent 40G client cards: 4x10G multi-rate, 40G multi-rate
    • 10G: 4x10G multi-rate OTR
    • Ethernet: 200G eMOTR, 30G L2 MOTR
    • OTN modules: 8-port OTN Flex MOTR (10G), 1+8 port OTN Flex MOTR (20G)
    • SONET/SDH 10G ADM-on-a-blade: SuperMux
  • +Packet/OTN switched modules
    • 10x10G Packet/OTN
    • 100G DWDM, OTU4
    • 40G DWDM, OTU3
    • 16x2.7G OTN
  • +SONET/SDH switched modules
    • Ethernet: L2 service switch, PDH Gateway, EPL
    • Electrical: E1, DS1, DS3, EC-1, E3
    • Optical: OC-3/STM-1 through OC-192/STM-64
  • +Distributed Control Plane
    • Photonic, OTN, SONET/SDH
  • +Configurations
    • Unprotected
    • 1+1/MSP linear
    • 1+1 OTN line-side
    • 1+1 LAG
    • 1+1 Enhanced Trunk Switch (ETS)
    • 1+1 Transponder Protection Tray
    • 1+1 Optical Protection switch (incl. fast coherent switching)
    • 2-Fiber BLSR/MS-SPRing
    • 4-Fiber BLSR/MS-SPRing/HERS
    • UPSR/SNCP
    • ASNCP
    • Mesh restorable control plane connections at L0 and L1
    • RPR layer 2 protection
    • G.8032 ERP
  • +Common Equipment
    • Full common equipment redundancy
    • Field-replaceable units
    • -48Vdc input voltage range:
    • -40Vdc to -75Vdc
    • 24Vdc input voltage range: +20Vdc to +30Vdc
    • AC input voltage range: 90Vac to 264Vac
  • +Environmental Characteristics
    • Normal Operating Temperature: +5°C to +40°C (+41° F to +104° F)
    • Short Term Operating Temperature: -5° C to +55° C (+23° F to +131° F) for 6500-2/7/14; -5° C to +50° C (+23° F to +122° F) for 6500-32
    • Normal operating humidity: 5% to 85% RH
    • Earthquake/seismic: Zone 4